GAS LEAKAGE ALARM ELECTRONICS PROJECT

HOW TO MAKE A GAS LEAKAGE ALARM?

This is a basic electronic project of Gas Leakage Alarm, using a SEN-1327. The circuit diagram below shows the circuit of the gas leakage alarm. The circuit operates off a 9V PP3 battery. Zener diode ZD1 is used to convert 9V into 5V DC to drive the gas sensor module.



The SEN-1327 gas sensor module from RhydoLABZ is used in this circuit. Its output goes high when the gas level reaches or exceeds certain point.

A preset in the module is used to set the threshold. Interfacing with the sensor module is done through a 4-pin SIP header. An MQ-6 gas sensor is used in the gas sensor module.

As per its datasheet, it has high sensitivity to propane, butane, isobutene, LPG and natural gas. The sensor can also be used to detect combustible gases, especially methane.

This circuit has been tested with LPG gas and was found to work satisfactorily. Whenever there is LPG concentration of 1000 ppm (parts per million) in the area, the OUT pin of the sensor module goes high.

This signal drives timer IC 555, which is wired as an astable multivibrator. The multivibrator basically works as a tone generator.

Output pin 3 of IC 555 is connected to LED1 and speaker-driver transistor SL100 through current-limiting resistors R5 and R4, respectively. LED1 glows and the alarm sounds to alert the user of gas leakage. The pitch of the tone can be changed by varying preset VR1. Use a suitable heat-sink for transistor SL100.

No comments:

Post a Comment